spike2 v8 (Cambridge Electronic Design)
86
Structured Review
Cambridge Electronic Design
spike2 v8
Spike2 V8, supplied by Cambridge Electronic Design, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/spike2+v8/8+software+spike2+v/bio_rxiv__2025__10__10__681637-58-17-19
Average 86 stars, based on 1 article reviews
Spike2 V8, supplied by Cambridge Electronic Design, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/spike2+v8/8+software+spike2+v/bio_rxiv__2025__10__10__681637-58-17-19
Average 86 stars, based on 1 article reviews
spike2 v8 - by Bioz Stars,
2026-10
86/100 stars
Images
Related Articles
other:Article Title: Reverse re-modelling chronic heart failure by reinstating heart rate variability Article Snippet: Cardiovascular and respiratory parameters were recorded from conscious sheep in heart failure on a desktop computer with a CED micro 1401 interface and a data acquisition program (Spike2 Amplification:Article Title: Anodal tDCS improves neuromuscular adaptations to short-term resistance training of the knee extensors in healthy individuals Article Snippet: Electrodes were placed over the dominant vastus lateralis according to the SENIAM guidelines ( ) and were connected to a wired EMG system (CED 1902; Cambridge Electronic Design, Cambridge, UK). .. Signals were amplified [gain 1,000× for EMG and 300× for force (CED 1902; Cambridge Electronic Design, Cambridge, UK)], band-pass filtered (EMG only: 20–2,000 Hz), digitized (EMG: 4 kHz, force: 2 kHz; CED 1401; Cambridge Electronic Design), and analyzed offline ( Article Title: Anodal tDCS improves neuromuscular adaptations to short-term resistance training of the knee extensors in healthy individuals. Article Snippet: 23 Experimental studies showed improvement in physical performance following acute application 24 of transcranial direct current stimulation (tDCS).. This study examined the neuromuscular and neural 25 response to a single training session (Part 1) and after a 3-week resistance training (Part 2) performed 26 with the knee extensors, preceded by tDCS over the primary motor cortex.. Twenty-four participants 27 (age, 30 ± 7 years; stature, 172 ± 8 cm; mass, 72 ± 15 kg) were randomly allocated to perform either 28 resistance training with anodal tDCS (a-tDCS), or by a placebo tDCS (Sham). Article Title: Supraspinal, spinal, and motor unit adjustments to fatiguing isometric contractions of the knee extensors at low and high submaximal intensities in males Article Snippet: .. Signals were amplified [gain ×100 for EMG and ×300 for force (CED 1902)], band-pass filtered (EMG only: 20–1,000 Hz), digitized (EMG: 2 kHz; force: 5 kHz; CED 1401, Cambridge Electronic Design), and analyzed offline ( Isolation:Article Title: The computational rules of cross-modality suppression in the visual posterior sylvian area Article Snippet: Neural signals were amplified, band-pass filtered (400 – 5000 Hz), digitized, and recorded (AlphaOmega Instruments, Nazareth Illit, Israel). .. Spike times of single-neuron were isolated either with an online sorting module (AlphaLab SnR, Israel) or with offline sorting software Software:Article Title: The computational rules of cross-modality suppression in the visual posterior sylvian area Article Snippet: Neural signals were amplified, band-pass filtered (400 – 5000 Hz), digitized, and recorded (AlphaOmega Instruments, Nazareth Illit, Israel). .. Spike times of single-neuron were isolated either with an online sorting module (AlphaLab SnR, Israel) or with offline sorting software Article Title: Distinct role of primate DLPFC and LIP in hierarchical control of learned saccade sequences Article Snippet: .. Neural signals were recorded and sorted online using AlphaLab SnR (AlphaOmega Instruments, Nazareth Illit, Israel) or sorted offline separately using the software |
